Basic Training
- 8 × 300 W LED floodlights (2,4 kW)
- Calculated average illuminance ≈ 120 lx
- Mounted on existing fence posts where suitable
- Training, school and residential compound pitches

In 2026, football pitch lighting with an LED floodlight system costs roughly 120.000 – 550.000 ₺ per pitch. Below we work out every item from poles to the control panel, how many lux you need and the monthly electricity bill, one by one.
Figures are per-pitch package prices for a 25×45 m outdoor pitch, including poles, LED floodlights, control panel, cabling, earthing, installation and commissioning.



In 2026, lighting a 25×45 m outdoor football pitch costs roughly 120.000 – 550.000 ₺, including LED floodlights, poles, control panel, cabling and installation. Basic training lighting falls in the 120.000 – 200.000 ₺ band, the commercial standard in 200.000 – 350.000 ₺, and a system suited to tournaments and match recording in 350.000 – 550.000 ₺. In the commercial standard package, if 12 floodlights of 400 W run 5 hours a day, the monthly electricity bill comes to about ₺3.600 at an example price of 5 ₺/kWh.
How the commercial standard package (200.000 – 350.000 ₺) breaks down into items on a 25×45 m outdoor pitch. Item total = package price × share; unit price = item total ÷ typical quantity.
| Item | Typical quantity | Unit price | Item total | Share |
|---|---|---|---|---|
| LED floodlight (driver and bracket included) | 12 pcs | 5.300 – 9.300 ₺/pcs | 64.000 – 112.000 ₺ | 32% |
| Galvanized pole and concrete foundation | 4 pcs | 14.000 – 24.500 ₺/pcs | 56.000 – 98.000 ₺ | 28% |
| Lighting control panel and automation | 1 set | — | 20.000 – 35.000 ₺ | 10% |
| Underground cable, conduit and trench | 200 m | 120 – 210 ₺/m | 24.000 – 42.000 ₺ | 12% |
| Earthing (grounding) | 4 pts | 2.500 – 4.400 ₺/pts | 10.000 – 17.500 ₺ | 5% |
| Installation, aerial work platform, aiming and lux measurement | 1 lot | — | 26.000 – 45.500 ₺ | 13% |
| Package total | — | — | 200.000 – 350.000 ₺ | 100% |
In our turnkey per-m² prices, lighting accounts for about 8% on an outdoor pitch and 6% on an indoor pitch. The amounts below show the budget set aside for lighting on a pitch built from scratch; if a higher tier is requested, the difference is quoted as an extra item. For installation on an existing pitch, the package prices above apply.
| Pitch size | Area | Outdoor pitch | Indoor pitch |
|---|---|---|---|
| 20 × 40 m | 800 m² | 121.600 – 160.000 ₺ | 168.000 – 216.000 ₺ |
| 25 × 45 m | 1.125 m² | 171.000 – 225.000 ₺ | 236.250 – 303.750 ₺ |
| 30 × 50 m | 1.500 m² | 228.000 – 300.000 ₺ | 315.000 – 405.000 ₺ |
Calculation: area × turnkey price per m² (outdoor 1.900 – 2.500 ₺/m², indoor 3.500 – 4.500 ₺/m²) × lighting share. Figures are 2026 market estimates for Türkiye; the exact price is confirmed in a written quote after the site visit.
Sports lighting is specified by the European standard EN 12193, adopted in Türkiye as TS EN 12193. The standard defines three classes according to the level of play; choosing a package is really choosing which class your lighting should be close to.
School, residential compound and amateur training use. On an outdoor football field, average horizontal illuminance is typically around 75 lx. Because the ball is fast and the pitch is small in small-sided football, operators design well above this lower limit; that is why the value calculated for the basic package is higher.
Regional leagues, club matches and pitches rented out regularly. On an outdoor football field the typical average is around 200 lx, with more even light required across every point of the pitch. Our commercial standard package targets this level.
Top-level tournaments and matches with spectators. On an outdoor football field the typical average is around 500 lx, with the highest uniformity. If matches are recorded or broadcast, flicker-free light for the camera is added; our tournament package is designed close to this level.
Class values are the typical levels the standard gives for football; for indoor halls the standard sets higher values. Projects are based on the current text of the standard and a photometric calculation.
| Pitch size | Poles (qty × height) | LED floodlights | Installed load | Average illuminance | Monthly electricity |
|---|---|---|---|---|---|
| 20 × 40 m 800 m² | 4 × 8 m | 8 × 400 W | 3,2 kW | ≈ 230 lx | ₺2.400 |
| 25 × 45 m 1.125 m² | 4 × 10 m | 12 × 400 W | 4,8 kW | ≈ 250 lx | ₺3.600 |
| 30 × 50 m 1.500 m² | 6 × 10–12 m | 16 × 400 W | 6,4 kW | ≈ 250 lx | ₺4.800 |
Average illuminance was calculated with a rough check formula: total power (W) × 130 lm/W × 0,45 utilization factor ÷ area (m²). Monthly electricity: 5 hours a day, 30 days, example price of 5 ₺/kWh. Quantities and heights are typical examples; the exact layout is set by a site-specific photometric calculation.
The part most often left out of quotes is the installation behind the floodlight. The control panel, cabling and earthing together make up about 27% of the package price.
Circuit breakers, a residual current device (RCD), contactors and an astronomical time switch. Splitting the floodlights into two circuits, half pitch and full pitch, cuts consumption during training hours. Share of the package: 10%.
Cables run inside corrugated conduit through a trench to the poles. The cross-section is calculated from the installed load and the distance between panel and pole; on long runs it is increased to limit voltage drop. Share of the package: 12%, rising linearly with cable length.
Every pole is earthed and bonded to the main earthing bar. Because the perimeter fence is metal, earthing and residual current protection are a direct life-safety item; earth resistance should be measured at handover. Share of the package: 5%.
A new pitch needs an electricity connection, and an existing facility often needs a capacity upgrade. Application, connection and deposit fees depend on the distribution company's tariff. They are not included in the package prices and should appear as a separate line in the quote.
You pay for installation once, and for electricity every month. We show the formula openly so you can recalculate with the unit price on your own bill.
Monthly cost (₺) = installed load (kW) × hours per day × days × electricity unit price (₺/kWh)
Example, commercial standard: 4,8 kW × 5 hours × 30 days = 720 kWh × 5 ₺/kWh = ₺3.600 / month
| System (25×45 m) | Installed load | Daily use | Monthly consumption | Monthly cost | Annual cost |
|---|---|---|---|---|---|
| Basic Training · outdoor pitch | 2,4 kW | 5 hours | 360 kWh | ₺1.800 | ₺21.600 |
| Commercial Standard · outdoor pitch | 4,8 kW | 5 hours | 720 kWh | ₺3.600 | ₺43.200 |
| Tournament & Match Recording · outdoor pitch | 9,6 kW | 5 hours | 1.440 kWh | ₺7.200 | ₺86.400 |
| Indoor pitch · ceiling fixtures | 5,5 kW | 10 hours | 1.650 kWh | ₺8.250 | ₺99.000 |
| Old metal halide system · outdoor pitch | 13,2 kW | 5 hours | 1.980 kWh | ₺9.900 | ₺118.800 |
5 ₺/kWh is an example unit price including taxes (Turkish tariff); it varies with your supply tariff. We assumed 5 hours a day on an outdoor pitch, 10 hours on an indoor pitch and 30 days of use per month. Annual cost = monthly cost × 12.
On an outdoor pitch, light comes from poles along the edge of the pitch at a set angle. Cost is driven by pole height, foundations and wind load; the lights are on only in the evening. Because light spilling off the pitch reaches neighboring plots, the choice of optics matters.
On an indoor pitch the pole item all but disappears; the fixtures hang from the roof trusses. On the other hand, because the light travels a shorter distance, more fixtures of lower wattage are used, and scaffolding or a platform is needed for installation. The typical layout on a 25×45 m indoor pitch is 22 × 250 W, i.e. 5,5 kW.
The real difference is in operating cost. Under an opaque roof the fixtures are on during the day as well; in our calculation we took 10 hours of daily use for the indoor pitch, which gave a monthly cost of ₺8.250. A translucent membrane roof and daylight-sensor control bring this amount down.
Indoor football pitch construction Outdoor football pitch construction


Most older pitches still run 1.000 W metal halide or halogen floodlights. These lamps take minutes to warm up to full output when switched on, dim over time and, with their ballast, draw more than their rated power.
If the poles and cabling are sound, only the fixtures, control panel and installation are renewed in a retrofit. The bracket and pole connection are still checked, as the new fixture's weight and wind area may differ from the old one.
LED's second gain is in operation: the light comes on at full output instantly, switching it off and on between matches does not wear the lamp, and a dimmable driver can cut consumption in quiet hours. The calculation below shows only the saving from the difference in power; lower lamp replacement and maintenance costs are not included.
Powerful but poorly aimed light both dazzles players and draws complaints. Most fixes are cheap before installation and expensive after it.
Throws the light forward at an angle close to horizontal, so it reaches the middle of the pitch without the floodlight being tilted up too far. Both glare and light spilling off the pitch are reduced.
The higher a floodlight is tilted, the closer the light gets to players' eye level and to neighboring façades. Angles are set according to the photometric calculation and locked after installation.
Cuts the light escaping to the side that does not face the pitch. On poles along an edge facing a road, housing or a school, it makes a big difference for a small extra cost.
On a low pole the floodlight has to be tilted up further. A taller pole brings the light down more steeply, reducing glare but increasing pole and foundation cost.
Switching the lights off automatically after the last booking and dimming them in quiet hours cuts both the bill and late-night complaints.
During the site visit, windows and roads around the pitch are marked, and the light falling in those directions is checked in the calculation. Replacing fixtures later costs more than this calculation.
These eight factors usually explain the gap between two lighting quotes for pitches of the same size.
| Factor | Direction | Size of impact |
|---|---|---|
| Target illuminance level (tier) | ↑↑ | The biggest factor: at mid-range values the tournament package costs about 2,8 times the basic package. |
| Mounting on fence posts (where suitable) | ↓ | The pole item (28% of the package) drops sharply; a structural check is essential. |
| Independent tall poles (10–12 m) | ↑ | Thicker poles, larger concrete foundations and a crane. |
| Distance between control panel and pitch | ↑ | Cabling (12% of the package) rises linearly with length; on long runs the cross-section grows too. |
| Dimming and automation | ↑ / ↓ | The control panel item grows, but the monthly electricity bill falls. |
| Flicker-free drivers and camera recording | ↑ | Fixture unit price rises; not needed if nothing will be recorded. |
| Ceiling mounting on an indoor pitch | ↕ | Poles go; the number of fixtures and the need for scaffolding or a platform increase. |
| Capacity upgrade or new connection | ↑ | A separate budget set by the distribution company's tariff; not included in the package price. |
Five steps from site visit to measured handover. On a new pitch, pole foundations are dug together with the groundworks.
Pitch size, pole positions, panel location and neighboring façades are determined; the lighting calculation is made for the target tier.
Installed load, cable cross-sections and the panel diagram are worked out; a capacity upgrade application is made if needed.
Pole foundations are poured, cable trenches are dug and earthing is installed.
Poles are erected, floodlights are fitted with their brackets, and the panel and automation are commissioned.
Floodlight angles are set to the calculation, lux levels are measured on the pitch and the pitch is handed over.
Partly, on most pitches. Fence posts are usually 4–6 m tall, so to spread the light evenly across the pitch the posts are often extended or separate poles are added at the corners. Before mounting, the post's wall thickness, its foundation and the wind load of the floodlight are checked. If they pass, the pole item in the package drops noticeably.
It does if the installed load exceeds your current contracted capacity. The Commercial Standard package draws about 4,8 kW; if, together with changing rooms, hot water and heating, the total load goes above the contracted capacity, an upgrade application is made to the electricity distribution company. Connection fees and deposits depend on the local utility's tariff and are not included in the package prices.
Lifetime is usually stated on the product datasheet as an L70 or L80 value, i.e. the number of hours until the luminous flux drops to a given percentage. On a pitch lit 5 hours a day, a rating of 50.000 hours corresponds to roughly 27 years. In practice the driver sets the lifetime first; a failed fixture is replaced on its own, without dismantling the whole system.
On a new pitch, pole foundations and cable trenches are dug during the groundworks, and the concrete foundations are left to cure. On a pitch where the poles are already in place, mounting, panel connection, aiming and lux measurement usually take a few working days. If a capacity upgrade is needed, the utility's approval time is added to the schedule separately.
First the floodlight's tilt angle is reduced and its direction corrected. If that is not enough, fixtures with asymmetric optics, visors or back-light shields are added. If neighboring façades are marked in the calculation before installation, no correction cost arises later; switching the lights off automatically at a set time also heads off complaints.
With low-quality drivers the light flickers faster than the eye can notice. A camera picks this flicker up as horizontal bands and pulsing in the footage, especially at high frame rates and in slow motion. On a pitch where a recording or live-streaming system will be installed, fixtures with low-flicker drivers are chosen; this is one of the items that raises the price of the tournament tier.
Yes, if it is planned from the start. Cable cross-sections, panel capacity and pole positions can be built for the target tier, with floodlights added in stages. Thin cabling and a small panel sized for the basic package, however, have to be redone during an upgrade; in that case the amount saved on the initial investment is paid back in the second phase.
With a dimmable LED driver, consumption falls roughly in proportion to the light level. In the Commercial Standard package, dimming the lights to 50% for 2 hours a day saves about 144 kWh a month, or ₺720 at an example price of 5 ₺/kWh (4,8 kW × 0,5 × 2 hours × 30 days).
If the roof lets light through (translucent membrane, roof lights), some of the fixtures can be switched off during daylight hours; under an opaque panel roof they stay on all day. That is why we assumed 10 hours of daily use in the indoor pitch cost calculation. With daylight-sensor control, only the fixture groups that are needed are switched on.
Choose size, turf and extras to see your pitch's total budget.
Base, drainage, turf, fencing and lighting from a single contractor.
Steel structure, roof covering and ceiling lighting.
Perimeter fencing with galvanized posts suitable for floodlight mounting.
Share your pitch size and the condition of your existing poles and electrics; we will run the lighting calculation during the site visit and prepare an itemized quote.